Application Note: Video - ANV087
Best Practices for Using the DH03 I/O Module
2025-08-08 Revision 1.0
This Application Note is intended for system integrators, security professionals, and resellers looking to deploy comprehensive I/O integration solutions that connect external devices to Brivo Eagle Eye Video. It targets technicians who perform installations of the Brivo Eagle Eye DH03 (SDUH-003a) I/O+Audio module for automated security systems in a variety of scenarios.
This Application Note provides insights into the Brivo Eagle Eye DH03 I/O+Audio module, which bridges external security devices with the Brivo Eagle Eye VMS to create unified, automated security systems. Proper installation and configuration of the DH03 module is critical for the reliable integration of legacy and modern devices. Improper setup can result in missed triggers, communication failures, or unreliable automation. This Application Note explains best practices for DH03 installations and common pitfalls to avoid.
This Application Note is not exhaustive. Please use and adapt this information for your specific DH03 deployments.
Modern security operations require seamless integration between cameras, sensors, alarms, and access control systems. Traditional security infrastructure often struggles with:
Isolated systems - Cameras, alarms, and sensors operating independently
Manual response delays - Security events requiring human intervention
Legacy device incompatibility - Older analog systems are unable to integrate with modern VMS.
Complex multi-vendor management - Disparate systems require separate interfaces.
Limited automation capabilities - Systems are unable to trigger coordinated responses across devices.
The Eagle Eye DH03 I/O+Audio module is designed to unify these disparate systems into a single, intelligent security platform.
The Eagle Eye DH03 15W SIP I/O Module (EN-SDUH-003a) has the following key features:
Expanded I/O Capability:
2 GPIO input channels for sensors, buttons, and switches
1 GPIO output channel for device control
2 relay output channels for controlling lights, alarms, and access devices
Flexible port association with multiple cameras per bridge
Advanced Audio Integration:
Analog-to-IP Audio Migration - Converts traditional speaker, mic, and headset devices into SIP-compatible IP endpoints
Two-Way Intercom Support - Interfaces with existing audio hardware via dedicated mic, speaker, and headset ports
48 kHz OPUS Codec - Ensures high-fidelity audio quality for both live and recorded content
Pre-Recorded Message Support - Stores and plays WAV/MP3 audio files based on VMS events, button presses, or I/O triggers
Dual SIP Account Support - Direct IP calling and multicast RTP capabilities
Audio Codec Support:
OPUS 48 kHz for high-quality real-time communication
MP3 44.1 kHz for pre-recorded content
G.722 and G.711 (PCMU/PCMA) for legacy compatibility
Support for WAV and MP3 pre-recorded audio files
Network and Protocol Support:
10/100 Mbps Ethernet connectivity (RJ45)
Cloud VMS integration with real-time event synchronization
Rule-based automation and alerting capabilities
The DH03 15W SIP I/O Module is recommended for the following applications:
Door Station and Intercom Integration:
Entry points, lobbies, and secure access areas
Converting analog door stations to IP-based systems
Two-way communication with visitors and staff
Integration with existing intercom infrastructure
Intrusion Detection System Integration:
Motion sensors, door contacts, and glass break detectors
Alarm triggering and automated response workflows
Legacy security system modernization
Multi-zone monitoring and control
Panic Button + 2-Way Audio Systems:
Retail stores, schools, financial institutions, and healthcare facilities
Emergency response with immediate audio communication
Automatic camera activation and monitoring center alerts
Pre-recorded emergency announcements
Paging and PA System Modernization:
Converting analog paging systems to IP-based control
Event-driven audio announcements via Cloud VMS
Multi-zone broadcast control with external amplifiers
Scheduled and triggered audio messaging
Automated Access Control:
Gate operators, door strikes, and barrier controls
License plate recognition triggers for access automation
Lighting control based on detection events
Audio confirmation for access events
Building Automation Integration:
HVAC control relays and environmental sensors
Facility management system integration
Energy management and equipment control
Automated building response systems
Legacy System Integration:
Energy, industrial, and government facilities
Vibration sensors, environmental monitors, and safety systems
Modernization without full infrastructure replacement
Cost-effective migration to IP-based systems
Network Infrastructure:
10/100 Mbps Ethernet connection with PoE capability (IEEE 802.3af) or separate 12-24V DC power supply
Reliable IP network connectivity to Eagle Eye Switch/Bridge/CMVR
Audio System Requirements:
Compatible analog audio devices (microphones, speakers, headsets)
Proper impedance matching for audio inputs and outputs
Audio cable routing and grounding considerations
Acoustic design for optimal audio performance
I/O Device Compatibility:
GPIO input voltage compatibility (verify with existing sensors)
Relay output current rating verification (up to device specifications)
Signal conditioning requirements for analog devices
Proper electrical isolation and protection
Enclosure Placement:
Install in environmentally controlled locations when possible (security panels, telecom closets)
Compact metal enclosure (112 × 105 × 29 mm) suitable for behind-panel mounting
Ensure adequate ventilation and service access
Maintain separation from high-power electrical equipment
Connection Best Practices:
Use appropriate cable types for audio, I/O, and network connections (Cat5/6, 18/2, 22/2 etc)
Implement proper grounding techniques for audio quality
Maintain separation between power and signal cables
Secure all connections to prevent accidental disconnection
Audio Installation Considerations:
Position microphones to minimize feedback and ambient noise
Install speakers for optimal coverage and intelligibility
Consider acoustic environment and background noise levels
Test audio quality under actual operating conditions
Planning Phase:
Map existing devices and their integration requirements
Identify camera associations for each I/O port
Plan automation rules and response workflows
Document legacy system specifications
Installation Guidelines:
Install in environmentally controlled locations when possible
Ensure proper grounding and electrical isolation
Use appropriate cable types for I/O connections
Maintain separation between power and signal cables
Configuration Steps:
From Dashboard, select Add Device (“+” icon top right above dashboard)
Select “Speakers”
Add Device (no need to configure username or password)
After Speaker is added, locate it from the bridge it is connected to in Dashboard, and go to Settings (Kebab menu on far right of page)
General tab, Configure Name, add Notes or Tags
Audio tab:
Audio mode:
Disabled: No Audio functionality needed
2-way audio: Audio can be sent down to an attached speaker, and Audio can be received to the VMS while the session is active (requires a microphone in the location of the speaker)
Talk down: Audio can be sent down to an attached speaker.
Either the Audio function from Cloud VMS will be initiated at the Cloud VMS user side. The ability to talk down or listen back will be dependent on the device the user is using.
Ex. From a browser on a Laptop, the session will use the laptop's built-in speaker and microphone to initiate communication. The browser may ask for permission to use the Laptop devices before the connection is made.
Protocol: Currently, only SIP is supported.
SIP username & SIP password: These are not needed for support through the Cloud VMS.
Speaker login & Speaker password: Only required if changed from the default.
Associate speaker with cameras: Drag the Unlinked cameras to the Linked cameras box to enable session communication through these camera devices
I/O tab:
Input ports: Input 1 and Input 2 settings
Enable port: Use these ports to receive input signals from a connected I/O device
Name: Name of the connected I/O device
Idle circuit state: This sets whether the port is configured for Normally Open or Normally Closed circuits
Port status: Shows whether the port is currently active or idle
Show toggle on video: Allows you to see the port status in camera view (whether the port is active or idle). The Icon can be set to a device type that relates to the signal
Record when active: This option allows you to trigger video recording for the camera when a signal activates this input.
Output ports: Input 1 and Input 2 settings
Enable port: Use these ports to send output signals from a connected I/O device.
Name: Shows the name of the connected I/O device.
Idle circuit state: This sets whether the port is configured for Normally Open, or Normally Closed circuits.
Port status: Shows whether the port is currently active or idle.
Toggle port status: Allows you to activate/ deactivate the relay port
Show toggle on video: Allows you to control the relay port in camera view (whether the port is active or idle). The Icon can be set to a device type that relates to the signal.
Record when active: This option allows you to trigger video recording for the camera when a signal activates this input.
Input to Output Automations: Use the Automations features to enable Input relay triggers to automatically send relay output triggers.
From Enhanced Web Application (webapp.eagleeyenetworks.com):
Automations: Menu item from Left Hand menu in Webapp (Alerts/ Rules/ Actions)
Rules: From Rules page, select “+” icon on top right of page
Rule name: Name the Rule
Source: Choose “Devices”
Priority: Set the priority of the alert (self-assigned value)
Notes: Add any notes regarding the rule (not required)
Alert type: Choose “Input triggered”
When: Choose a schedule for when the alert is active
Device type: Choose “Speakers”
Speakers: Choose the I/O device for which the Rule is needed.
Input port: Choose the Input number/name where the trigger will activate for the rule to fire
Actions: Apply an existing Output Port Action, or create one with the “+” icon
Add action:
Action name: Name of action
Action type: Choose “Output port”
Device: Choose the I/O device for the Output relay
I/O port: Choose which port to trigger
Duration in secs: Choose how long the Output relay should be activated for the action
Video Event to Output Automations: Use the Automations features to enable a video analytic event to automatically send relay output triggers
From Enhanced Web Application (webapp.eagleeyenetworks.com):
Automations: Menu item from Left Hand menu in Webapp (Alerts/ Rules/ Actions)
Rules: From Rules page, select “+” icon on top right of page
Rule name: Name the Rule
Source: Choose “Video”
Priority: Set the priority of the alert (self-assigned value)
Notes: Add any notes regarding the rule (not required)
Alert type: Choose the type of Video Analytic applied to the selected cameras
When: Choose a schedule for when the alert is active
Cameras: Choose which camera devices have the Alert type enabled, and should activate the Relay on alert condition
Actions: Apply an existing Output Port Action, or Create one with the “+” icon
Add action:
Action name: Name of action
Action type: Choose “Output port”
Device: Choose the I/O device for the Output relay
I/O port: Choose which port to trigger
Duration in secs: Choose how long the Output relay should be activated for the action