Application Note: Video – ANV039
Best Practices for Brivo Eagle Eye Bridge/CMVR Installations
2024-11-12 Revision 2.1
This Application Note is intended for installers and technicians who perform on-site installations of Eagle Eye Bridges and CMVRs for Brivo Eagle Eye Video.
Proper installation of a Brivo Eagle Eye Bridge/CMVR is crucial to ensuring reliable operation for customers. Improper installation can result in problems such as overheating, offline cameras, or reliability issues. This Application Note explains best practices for Bridge/CMVR installations, as well as practices to avoid.
Brivo provides a variety of Bridges/CMVRs to choose from based upon the application and the installation environment. We strongly recommend using a rack-mount bridge if the customer has a rack. A rack-mount Bridge/CMVR is the preferred solution in all cases where a rack is present. It will provide the most reliable operation and cleaner, more reliable wiring. A Compact Bridge/CMVR, to which this Application Note mainly applies, should be used only when a rack is not available.
This Application Note gives examples for different types of installations. It is by no means exhaustive, nor is it the only way to properly install equipment. Please adapt and use this information for your installations.
Bridges and CMVRs communicate exclusively with the Brivo Eagle Eye Cloud Data Center and therefore do not require any inbound ports to be open or firewall rules to be created. The image below shows the preferred wiring method for a small-scale installation. Note that greater security is achieved when the cameras are located on the CamLAN, which is highly recommended.
Typical wiring diagram for an Eagle Eye Bridge/CMVR
There is no need to perform any software, firmware, or security updates on an Eagle Eye Bridge/CMVR. Security and updates are managed remotely by the system. When the Bridge/CMVR is initially powered on, it will check for firmware updates and automatically apply them. Please allow the Bridge/CMVR update to complete before power cycling or disconnecting from the internet to avoid issues.
For a quality mounting and installation of the Brivo Eagle Eye Compact Bridge/CMVR, make sure to have the following:
Brivo Eagle Eye Compact Bridge/CMVR (Provided by Brivo)
AC power cord and power supply (Provided by Brivo)
Eagle Eye Installation Kit - tie wraps, velcro, screws, etc. (Provided by Brivo)
Ethernet cables (Not provided)
PoE switch (Provided if purchased through Brivo)
Tools: power drill, crimpers, snips, level, glow rod, Ethernet cable tester, RJ45 mod connectors, tie wraps, ladder, patch cables, knife, screws (Not provided)
Plywood if you are installing onto a wall. We recommend ¾” or 20mm plywood. This gives enough thickness for screws to be installed, hold, and not protrude from the back. Additional details and pricing links are listed within the Do’s and Don’ts section at the bottom of the document. (Not provided)
Cameras (Provided if purchased through Eagle Eye Networks)
UPS (Uninterruptible Power Supply): A UPS is needed for a quality and reliable installation. The UPS will eliminate power issues for all electronic equipment and should be used to ensure reliable operation. The UPS should also be used on the router/modem.
Brivo Eagle Eye Bridges/CMVRs with a ‘+’ in the model have a blue chassis and include an LCD screen. See the Application Note, AN050 - Understanding the OLED Display on Eagle Eye Compact Bridges and CMVRs on the Compact Bridge/CMVR for details on the LCD screen operation.
Example Compact Plus Model Bridge (304+)
Example Compact Plus Model Bridge (504+)
Plus model Bridges/CMVRs come with an Installation Kit.
Compact Plus Model Bridge/CMVR Installation Kit
Compact Plus Model Bridge/CMVR Installation Kit contents
The Brivo Eagle Eye Installation Kit includes:
5 Velcro Cable Ties (3 x 150mm, 2 x 250mm) - Bundles cables/cords together and provides mounting to the wall. The holes are for securing the straps to the plywood or wall with screws. Can also be used to mount separate power supplies. Good for cables because you can open them up and add a cable to the bundle (unlike tie wraps, where you have to cut and replace).
10 Mountable Nylon Zip Ties (5 x 250mm, 5 x 300mm) - Used for mounting power supplies, power strips, and cables to the wall. Also used to strain-relieve power cords so they don't get accidentally pulled out.
1 Eagle Eye Networks Strain Relief Clip - Used to hold cables in place and eliminate accidentally pulling them out. Good for power supply/strip cords and for Ethernet cables. Can also be opened once secured so that cables can be added as needed.
16 Screws - Used for securing the Bridge/CMVR cables and all the components. If installing on drywall/stucco, you need to use a piece of plywood to achieve a reliable installation.
#8, 1.25” Modified Truss Head Screws (4) - Screws for mounting the bridge, tie wraps, Velcro, and Cable Clip to plywood.
#6, 1.25” Drywall Screws (12) - Used for mounting cables and cable clips to drywall or other surfaces where a longer screw is needed.
Installation Kit Card - Find a QR code here to quickly download the Eagle Eye Assistant App and also learn how to share your Eagle Eye Install to social media using the hashtag #EagleEyeInstall.
Also important:
Power Cord Clip (attached to the Bridge) - Keeps the power cord secured to the Bridge so that it does not accidentally pull out.
Standard (non-Plus) Compact Bridges/CMVRs include a VESA mounting bracket.
VESA mounting bracket that is included with the standard version of Bridges/CMVRs
The VESA mount is only used when installing vertically to a surface like a wall. The mount is secured directly to the plywood, and then the Bridge/CMVR is connected to the mount. Note that the mount includes an arrow indicating which side should face up when mounting. Always have the VESA mount arrow facing up. Make sure that the 2 metal clips are facing out, as that is what’s used to lock the Bridge/CMVR in place to the mount.
Use the 2 raised clips on the VESA mount to clip into either the vertical or horizontal grooves on the bottom side of the Bridge/CMVR. Make sure the power cord and Ethernet cables are not pinched when clipping in and that they can be properly routed and secured. Do not allow cords to hang freely.
Installations can be broken down into 4 types: Wall-Mount Installations (directly to the wall or on a wall-mounted rack), Shelf Installations, Outdoor Installations, and Rack Installations. This document focuses mainly on indoor installations. Refer to the Application Note, AN060 - Understanding Eagle Eye Cabinet Systems Outdoor Operating Conditions and Enclosure Ratings for additional information. Remember, if you have a regular rack, use a rack-mount Bridge or CMVR. Do not use a Compact Bridge if you have a rack.
A wall-mount installation will generally be more reliable than a shelf installation because the equipment and cables are fixed in place and less likely to be jostled. When the Bridge/CMVR is wall-mounted, it is secured, and future installers of other equipment won't stack items on top of it or accidentally knock cables loose. This all means fewer potential trips to repair.
If given the option, a wall-mount installation is preferred and has several advantages. Namely, the heat dissipation from the chassis is more effective. When the Bridge/CMVR is vertically mounted, it best preserves the installation so that, in the future, when others use the same space, they don’t stack things on top of it or accidentally knock it loose.
Note: Enterprise CMVR units (520, 620, 820) should never be wall-mounted. This can damage the internal components and may void the warranty.
There are several key rules to a good wall-mount installation:
Use a piece of plywood (at least 3/4” thick) mounted securely to the studs or concrete. Definitely want to hit the studs in the walls if you can. We often use 24” x 24” pre-cut pieces available from Lowes or Home Depot. No cutting needed.
Securely mount the components to the plywood with the Trust Head Screws, leaving enough space for cables between them.
Securely mount a power strip to the plywood.
Mount the power supplies using tie wraps or other hardware - do not let them hang.
Neatly route the wires and secure them to the plywood.
Mount the UPS to the plywood or wall.
Ensure that all power cords and cables have adequate strain relief and are securely attached to the panel so that if they are accidentally pulled, they do not come out.
Always use plywood when mounting on drywall to ensure installation stability and prevent screws from falling out and hardware from coming loose. The cables should be secured with Velcro straps and fastened to the wall through the hole in the Velcro strap using the screws in the Installation Kit. Use the VESA mounting bracket for the older model 304/324 Bridge/CMVR installs.
Make sure to mount the power supply and network switch to the wall and do not let cords and cables hang. Most Eagle Eye Compact Bridges/CMVRs also have a cable clip attached to the chassis to help prevent the power cable from being pulled out.
Sequence of the installation - step-by-step process:
Locate a section of the wall in the room where you will do the install. Make sure you can get power (wall outlet on the same wall is good). Clear the area on the wall.
Locate the studs if mounting to drywall (use a stud finder or the knocking method).
Attach the plywood to the wall. Use long screws that are sturdy. If attaching to concrete, use anchors and pre-drill the holes (lag bolts work well).
Determine how power and network cables will route to the mounting plywood. Determine power routing from the outlet using a power strip mounted to the board. Make sure the power cord is long enough. Determine the network cable entry/exit location (top, bottom, or side).
Determine the location of the switch, bridge, power strip, UPS, and power supplies. Remember to leave room for the cables between them. Do not mount them close together. They need space for proper cooling. It is best to place the switch near the network cable entry point.
Securely mount the hardware to the board.
Securely mount the power supplies to the board using tie wraps.
Route the power cords and secure them to the board using tie wraps or Velcro ties.
Connect the network cables and route them.
Organize the network cables and secure them to the board using the Velcro ties.
See examples of Wall Mount Installations with best practices and things to avoid below:
GOOD EXAMPLE: Do coil cables and secure them using velcro straps, tie-downs, and screws.
GOOD EXAMPLE: A Bridge mounted with painted plywood (nice touch), clean cables, and securely fastened hardware. Note the UPS power solution.
GOOD EXAMPLE: Do leave enough room for Ethernet cables to connect to the switch.
GOOD EXAMPLE: Do monitor the temperature of the room where the Bridge/CMVR has been installed.
GOOD EXAMPLE: Securely mount the power strip.
GOOD EXAMPLE: Securely mount the power supply using zip ties and screws to prevent cords from accidentally falling out.
GOOD EXAMPLE: Do use a UPS battery backup for your installation. This provides more reliable power and avoids corruption. In addition, the cameras will operate during power outages.
GOOD EXAMPLE: Do mount to plywood with at least 4 large screws directly into studs or use large anchors.
GOOD EXAMPLE: Secure the power cord to the Bridge/CMVR using the provided cable clip to prevent it from being pulled out.
GOOD EXAMPLE: Use strain relief on all power cords to prevent them from being pulled out accidentally. The installation needs to last many years. However, be cautious not to bend the cord too much.
GOOD EXAMPLE: Do strain relief on the cords/cables and secure them to the wall. DON'T try to mount directly to drywall - the screws and mounts will tend to work loose over time.
GOOD EXAMPLE: Secure the power supply to the wall, ensuring it does not come loose and cords don’t fall out. Do leave enough room between devices to avoid overheating.
GOOD EXAMPLE: Secure the power strip to the wall to prevent it from being taken, and strain-relieve the cable so it's not accidentally pulled, causing issues.
BAD EXAMPLE: DO NOT attach the power supply to the Bridge/CMVR, as this can result in overheating. DO NOT place the power supply on top of the Bridge/CMVR. DO NOT place anything on top of the equipment.
BAD EXAMPLE: DO NOT set equipment on top of the Bridge or the Switch. Stacking power supplies or equipment will reduce reliability due to heat. It will also fall off and likely disconnect. Remember, other people will come into the area and bang and bump your installation.
BAD EXAMPLE: DO NOT fail to secure the Bridge/CMVR, cables, and cords to the wall. Always secure the equipment to the wall and ensure that cords and cables have been organized and secured.
Note: Enterprise CMVR units (520, 620, 820) should never be wall-mounted. This can damage the internal components and may void the warranty.
If installing a Rack-Mountable Bridge/CMVR and mounting inside a rack is not possible, a Rack-Mounted Wall Installation is recommended rather than a shelf installation. A Wall-Mountable Rack is specifically designed for this type of situation. Click on this hyperlink to see our recommendation. Please use caution with a metal wall-mountable rack due to additional concerns about grounding and/or electromagnetic interference (EMI).
Folding Steel Wall-Mountable Simple Vertical Rack and Server Rack (2U35P)
Wall-Mountable Rack installation examples below:
GOOD EXAMPLE: Do use a wall-mountable rack over plywood, secure cables, and utilize a UPS battery backup solution.
GOOD EXAMPLE: Do use a wall-mountable rack, strain relief cords, and secure them to the plywood.
There are several key rules to a good shelf installation:
Use a shelf secured to wall studs (or plywood), or use quality wall anchors through the drywall.
Mount the bridge securely to the shelf using screws (avoid the use of adhesives). Not doing this puts the Bridge/CMVR at risk of being knocked off and becoming damaged or disconnected.
Consider the space the shelf provides to best determine if there is space for additional equipment. If not, additional equipment should be mounted to the wall as described in the previous section.
As indicated above, mount the power supplies using tie wraps or other methods, and neatly route and secure the wires.
Neatly route the wires and secure them to the wall or shelf.
Strain-relieve the cords so that if they are accidentally pulled, they do not come out.
Installing a Bridge/CMVR on a shelf is possible if wall mounting is not possible. First, make sure the shelf is properly anchored to the wall and can support the weight of the Bridge/CMVR and any other items it will hold. If installing a shelf as part of the installation, it is recommended that plywood be used or that it be secured directly to studs. The Bridge should always be screwed down to the shelf if possible.
The power supply should be either mounted to the wall with cables secured or positioned and secured to the shelf so that it doesn’t come loose or become disconnected. Always use the strain relief clip to secure the power cable to the Bridge/CMVR.
The switch (and its power supply if it has a separate one) should either be mounted to the wall with cables secured or positioned and secured to the shelf so that it doesn’t come loose or become disconnected.
The router should not be in close proximity to the Bridge/CMVR due to overheating concerns. If the shelf size permits, the router and power cables can be secured on top of the shelf, but leave enough room between the Bridge/CMVR to prevent overheating and keep cables from getting rattled loose.
Remember to use high-quality, short Ethernet cables whenever possible to avoid entanglement and messy installations.
GOOD EXAMPLE: Do use a clean, organized shelf free of clutter, with devices, cables, and cords neatly organized. There are no cords hanging down, and the cables are secured with the strain relief clip.
GOOD EXAMPLE: Do use a UPS solution, secure power cords, and ensure there is space between all devices to help prevent overheating.
DO NOT leave the sticker on the Bridge/CMVR or leave cables and cords unsecured. DO NOT allow the switch and/or power supply to be on top of or in close proximity to the Bridge/CMVR. DO secure the Bridge, router, and cables to the wall.
BAD EXAMPLE: DO NOT let cables, cords, and power supplies hang loose. DO NOT stack the switch on top of the Bridge/CMVR.
BAD EXAMPLE: DO NOT stack electronics on top of each other as this can cause overheating. DO NOT allow cords to be free-hanging and unsecured as they may come loose or become disconnected.
BAD EXAMPLE: DO NOT stack electronics on top of each other as this can cause overheating concerns. DO NOT allow cords to be free-hanging and unsecured as they may come loose or become disconnected. DO organize cables and secure them.
BAD EXAMPLE: DO NOT leave cables hanging loose. Always secure them to each other and the wall.
BAD EXAMPLE: DO NOT stack books or papers on top of the Bridge which can block ventilation and lead to overheating.
If performing a shelf installation is not possible due to concerns over damaging the shelf when screwing in and securing the equipment, adhesive tape can be utilized. Make sure to use a high-quality double-sided adhesive tape to secure the equipment to the shelf. Click on the hyperlink to see our recommendation: Amazon.com: Double-sided, Heavy Duty, Waterproof Mounting Tape.
Double-sided, heavy-duty, waterproof mounting adhesive tape
Use a rack mount if you have a rack, but know that Compact Bridges/CMVRs can also be mounted within racks if available. Otherwise, mount the Compact Bridge/CMVR to a wall using plywood or install it on a shelf and secure it. If you are going to put it in a rack, ensure there is enough space, and make sure it goes on top of a shelf rather than directly on the PDU. Leave at least 1U between the Bridge/CMVR and any other equipment within the rack.
The recommended temperature range for a server room is 50-82 degrees, with the optimal range being 68-71 degrees. Having the Bridge/CMVR in a location that stays within the optimal server room temperature, in addition to a proper installation, is the best way to ensure reliability and keep from overheating. Any installation outside the recommended temperature range is not recommended and can lead to failure.
DO NOT use a Compact Bridge/CMVR if you have a rack. DO NOT leave the sticker with the Attach ID, as this is a security problem.
DO NOT do this.
For more details and examples of outdoor installations, see the Application Note AN060 - Understanding Eagle Eye Cabinet Systems Outdoor Operating Conditions and Enclosure Ratings.
It is recommended to use a UPS for powering all the cameras, routers, switches, and modems. Since a UPS works independently, it will continue to provide power when the main power supply fails.
For projects that do not use emergency power, a UPS is still recommended to ensure orderly system shutdowns and prevent disk corruption. If a disk becomes severely corrupted, files can be damaged, and the system could become unrecoverable.
Both battery backup and emergency power are recommended for video recording installations. Since the video system can still perform a hard shutdown during the transition to emergency power, having the UPS in place is necessary to prevent file corruption.
Recommendations for UPS solutions listed below. Smaller systems can use a UPS like the one below:
Larger systems can use a UPS like the one below:
Example wall-mounted installation with a UPS battery backup solution below:
DO use a UPS battery backup solution on your installations
DO:
Secure the Bridge/CMVR to a stable surface so it doesn’t become disconnected.
If mounting to a wall, ensure that the Bridge/CMVR is properly secured to plywood.
Refer to local guidelines and regulations regarding plywood specifications.
Using plywood will save time and money in the long-run. It should be considered standard for Compact Bridge/CMVR installations. It is sturdier than drywall, relatively inexpensive, can be replaced easily if needed, and is not conductive. Performing an installation with plywood to begin with will reduce the chance of issues that would require a site visit later. This can also be done in advance of visiting the site to further save time.
The dimensions of the piece of plywood should be a minimum of 16” wide to span across two studs. Sheets are sold as small as 2 ft. squares, but can be larger to save cost and cut later. Adjust the size accordingly and consider whether you’ll also mount the switch and/or other hardware to it before making a decision.
Pricing estimates are below for Lowe's and Home Depot (but are subject to change and can’t be guaranteed).
A ½” thick, 2 x 4 ft. sheet can be found for approx. $20–28.
A ½” thick, 4 x 8 ft. sheet can be found for approx. $40+.
If a plywood installation is not possible, drywall anchors must be used to secure the Bridge. Not doing this can leave the Bridge/CMVR vulnerable to coming loose and becoming disconnected.
If installing outdoors on stucco or cement, use a NEMA enclosure and wall anchors, and avoid damp areas or places where condensation can build up.
Use the material provided in the Installation Kit.
Using the power cable clip is key when mounting vertically on a wall, as the cord's weight could cause it to disconnect.
Screws are provided and should be used in the outer-edge holes for stability. However, if mounting on a DIN Rail is required, there are additional screw slots on each side of the device that can be used.
Bring a laptop, monitor, and keyboard, or use the Mobile Bridge Configurator.
If you have a mobile hotspot, you can connect the Bridge/CMVR with the USB cable to determine if there is a firewall issue on-site.
Get local network configuration information before the installation commences, if possible.
Send Eagle Eye Networks a picture of the installation or post to social media using the hashtag #EagleEyeInstall.
DON’T:
To prevent overheating:
Do not put items on top of the Bridge/CMVR.
Do not put the Bridge on top of other equipment or cables.
Do not block the ventilation of the Bridge/CMVR.
Do not attach a power supply to the Bridge/CMVR or switch.
Do not install a Bridge/CMVR in a tight space or cabinet without good air circulation.
Do not put it in a non-NEMA-rated enclosure/box.
Do not cover the Bridge/CMVR with papers or books, or stack anything on top of the bridge, as this can cause overheating and the bridge going offline.
Do not install the Bridge/CMVR in close proximity to other wiring, cables, electronics, or heat sources.
Do not install the Bridge/CMVR above a stove or on top of a refrigerator.
Do not stretch power cords too tightly or bend cables.
Do not let the power cord hang freely.
When installing on a shelf or within a cabinet, make sure the device is anchored and that cables will not be pitched when closing the door or accidentally pulled out.
Enterprise CMVR units (520, 620, 820) should never be wall-mounted. This can damage the internal components and may void the warranty.